3300 CE/3900 RC STRATUS SYSTEMS - ELECTRICAL TROUBLESHOOTING

Please refer to your owner's manual for detailed instructions. If you do not have an owner's manual please call
our Customer Service phone number to order one.
1.
Verify that all connections on the power control board are secure.
2.
Adjust the inductive switch to within 1/32" of the speed sensor disk.
3.
Test pins 2 and 3 of the battery connector for a minimum of 6.1 VDC.
4.
Plug battery connector back into power control board.
5.
Measure VDC between test points 7 and 12 of the power control board for a minimum of 6.0 VDC
6.
Test pins 1 and 2 of the inductive switch connector while pedaling. VAC should increase with RPM.
7.
Re-connect the inductive switch connector to the power control board.
8.
Measure VAC between test points 10 and 12 of the power control board while pedaling. Voltage should
increase with RPM.
9.
Unplug the alternator wiring connector from the power control board.
10.
Perform the Positive output to field test using alligator clips between the B+ and FLD terminals.
11.
Re-connect the alternator wiring connector to the power control board.
12.
Remove the diode from the FLD terminal of the alternator.
13.
Test the diode (Ohms). High reading in one direction, Low reading when leads are reversed.
14.
Re-connect the diode to the FLD terminal of the alternator.
15.
Test pins 1 and 2 of the load resistor connector for a reading of .5 Ohms.
16.
Ohm and cross check the main cable assembly.