Comtech EF Data LCS-4 Installation And Operation Manual page 83

L-band combiner switch
Table of Contents

Advertisement

LCS-4 L-Band Combiner Switch
Remote Control Operation
Command
Arguments
(Instruction
for Cmd or
Parameter
Code and
Response
Type
qualifier)
to Query
Switch
SGC=
56 bytes,
Global
with
Configuration
numerical
entries fixed
value
entries, and
delimiters
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Command or Query. Global configuration of Unit, in
the form:
SGC=abcdeffgghijklmmnnoopqrssstuvwxy'cr''lf]
where:
a = Tx LCS Function (STT)
b = BUC A Power Supply Enable (BSA)
c = BUC B Power Supply Enable (BSB)
d = BUC A Reference Osc. Enable (BRA)
e = BUC B Reference Osc. Enable (BRB)
ff = BUC A Current Window (BCA)
gg = BUC B Current Window (BCB)
h= BUC Fault Logic (BFL)
i = RX LCS Function (SRL)
j = LNB A Power Supply Enable (LSA)
k = LNB B Power Supply Enable (LSB)
l = LNB A Reference Osc. Enable (LRA)
m = LNB B Reference Osc. Enable (LRB)
nn = LNB A Current Window (LCA)
oo = LNB B Current Window (LCB)
p = LNB Fault Logic (LFL)
q = Ref Source select (RSS)
r = VCXO Power Control (VPC)
sss = Reference OSC. Adjust. (SRO)
t= Reference Fault Logic (RFL)
u = Cold Start Enable (CLD)
v = Redundancy Switch Control Mode (RAM)
w = Redundancy Switch Control Mode (MOD)
x = UPC Support (UPC)
y = Modem FSK control (FSM)
Response to
Command
(Target to
Controller)
SGC= (message ok)
SGC? (received ok,
but invalid
arguments found)
A-19
MN/LCS4.IOM
Query
(Instruction
code and
Response to query
qualifier)
(Target to Controller)
SGC?
SGC=
abcdeffgghijklmmnnoopqrssstuvw
xy
(same format as command
arguments)
Revision 1

Advertisement

Table of Contents
loading

Table of Contents