Comtech EF Data LCS-4 Installation And Operation Manual page 82

L-band combiner switch
Table of Contents

Advertisement

LCS-4 L-Band Combiner Switch
Remote Control Operation
Command
Arguments
(Instruction
for Cmd or
Parameter
Code and
Response
Type
qualifier)
to Query
Concise
N/A
41 bytes,
Alarm Status
numerical
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Query only.
Used to Query the Alarm status of the LCS-4 response
is comma delimited.
Example: CMS=abcdefghijklmnopqr'cr''lf'
where: a thru t = 0 or 1, 0 = OK 1 = FT
a = Main 48V Power Supply A Alarm
b = 12V Power Supply B Alarm
c = 12V Power Supply Alarm
d = +5V Power Supply Alarm
e = -5V Power Supply Alarm
f = BUC A Voltage Alarm
g = BUC B Voltage Alarm
h = BUC A Current Alarm
i = BUC B Current Alarm
j = BUC Switch Alarm
k = LNB A Voltage Alarm
l = LNB B Current Alarm
m = LNB A Current Alarm
n = LNB B Current Alarm
o = LNB Switch Alarm
p = Fan Current Alarm
q = REF Lock Detect PLL Alarm
r = BUC Redundancy Switch Alarm
w = LNB Redundancy Switch Alarm
t = Summary Fault Status
Response to
Command
(Target to
Controller)
N/A
A-18
MN/LCS4.IOM
Query
(Instruction
code and
Response to query
qualifier)
(Target to Controller)
CAS?
CAS=abcdefghijklmnopqr (see
description for details of
arguments)
Revision 1