Comtech EF Data LCS-4 Installation And Operation Manual page 10

L-band combiner switch
Table of Contents

Advertisement

LCS-4 L-Band Combiner Switch
Preface
E
S
LECTRICAL
AFETY
The LCS-4 has been shown to comply with the following safety standard:
EN 60950: Safety of Information Technology Equipment, including electrical business
machines.
The equipment is rated for operation over the range 100 - 240 volts AC. It has a maximum
power consumption of 2.9 amps.
F
USES
The LCS-4 is fitted with two fuses, one each for line and neutral connections. These are contained
within the body of the IEC power connector, behind a small plastic flap. For 115 and 130 volt AC
operation, use T3, 15A, TO.75A, 20mm fuses.
For continued operator safety, always replace the fuses with the
correct type and rating.
IMPORTANT
Environmental
The LCS-4 shall not be operated in an environment where the unit is exposed to extremes
of temperature outside the ambient range 0 to 50°C (32 to 122°F), precipitation,
condensation, or humid atmospheres above 95% RH, altitudes (un-pressurized) greater
than 2000 meters, excessive dust or vibration, flammable gases, corrosive or explosive
atmospheres.
Operation in vehicles or other transportable installations that are equipped to provide a
stable environment is permitted. If such vehicles do not provide a stable environment,
safety of the equipment to EN60950 may not be guaranteed.
viii
Revision 1
MN/LCS4.IOM