L-band combiner switch
Table of Contents

Advertisement

LCS-4 L-Band Combiner Switch
Remote Control Operation
Command
Arguments
(Instruction
for Cmd or
Parameter
Code and
Response
Type
qualifier)
to Query
Concise
N/A
32 bytes,
Utility Status
alpha
numerical
Retrieve
N/A
147 bytes,
Alarm Status
text
Description of Arguments
Note that all arguments are ASCII
numeric codes between 48 and 57.
Query only.
Used to Query the Utility status of the LCS-4 response
in comma delimited.
Example:
CUS=aaaaa,bbbbb,ccc.c,ddd.d,eee,f,g,h,'cr''lf']
where:
aaaaa = BUC A CAL Current
bbbbb = BUC B CAL Current
ccc.c = LNB A CAL Current
ddd.d = LNB B CAL Current
eee = Reference Adjust setting
f = External Reference Sense
g = BUC Online Status
h = LNB Online Status
Query only.
Used to Query the Alarm status of the LCS-4
Example: RAS='cr'
48VLT=OK'cr'
12VP1=OK'cr'
12VP2=OK'cr'
P5VLT=OK'cr'
N5VLT=OK'cr'
BUCAV=OK'cr'
BUCBV=OK'cr'
BUCAC=OK'cr'
BUCBC=OK'cr'
BUCSW=OK'cr'
LNBAV=OK'cr'
LNBAC=OK'cr'
LNBBC=OK'cr'
LNBSW=OK'cr'
FANMC=OK'cr'
REFLD=OK'cr'
BUCSW=OK'cr'
LNBSW=OK'cr'
SFLTS=ok'cr''lf']
Response to
Command
(Target to
Controller)
N/A
N/A
A-17
MN/LCS4.IOM
Query
(Instruction
code and
Response to query
qualifier)
(Target to Controller)
CUS?
CUS=x....x (see description for
details of arguments)
RAS?
RAS=x....x (see description for
details of arguments)