Drive Square; Calibration; Cleaning; Disposal - norbar PNEUTORQUE PTM series Operator's Manual

Ptm & ptme series nternal control (ic) shut-off tools
Hide thumbs Also See for PNEUTORQUE PTM series:
Table of Contents

Advertisement

Drive Square

To avoid internal damage (especially due to torque overload), the output drive square has been designed to
shear first. This saves major internal damage and allows easy square removal. For drive square part
numbers see page 5.
To replace drive square:
1.
Remove the air supply.
2.
Support tool in a horizontal position
3.
Remove the screw or spring pin, then remove drive square.
If the square has sheared it may be necessary to use pliers to remove the broken parts
4.
Fit new drive square.
5.
Fit new screw and tighten between 4 N·m to 5 N·m (for PTM52) or 8 N·m to 9 N·m (for PTM72/92/119)
or insert new spring pin.
6.
Connect air supply.
TIP:
If the drive square fails continually then seek advice from Norbar or a Norbar distributor.

Calibration

To maintain the Pneutorque
Contact Norbar or a Norbar distributor for more information.

Cleaning

Keep the tool in a clean condition to aid safety. Do not use abrasives or solvent based cleaners.

Disposal

Recycling Considerations:
Component
Handle
Gearbox (clockwise / counter-clockwise)
Gearbox (52mm / 72mm)
Reaction bar
FIGURE 11 – Drive Square Replacement
®
accuracy it is recommended the tool is recalibrated at least every 12 months.
Material
Aluminium case / Steel internals
Aluminium case / Steel internals
Steel with nickel plated case / Steel internals
PTM-52 is steel / PTM-72 is aluminium
17

Hide quick links: