Thermal Trip-Removal And Installation - Kohler Electric Shower Installation And User Manual

Electric shower
Table of Contents

Advertisement

Thermal Trip - Removal and Installation
WARNING! Isolate the electrical and water supplies before removing the cover. Mains
electricity connections are exposed when the cover is removed.
1.
Remove the three cover retaining screws, and the cover.
2.
Make a note of the positions of the wiring on top of the heater tank.
3.
Remove the screw that holds the green earth wire to the thermal trip.
4.
Ease the thermal trip away from the heater tank.
Brown
Red
Brown
5.
Remove the screws that hold the red and three brown wires on the thermal trip.
6.
Remove the thermal trip.
Caution! Do not press printed disc on the thermal trip as this will make the
component unserviceable.
Brown
Red
Brown
7.
Refit the components in reverse order. Make sure that the electrical wires are
installed in the correct positions.
Thermal Trip
Green Earth
Wire
Thermal
Trip
39