7.
Lift out the flow regulator assembly,
switch assembly and the heater tank
from the case.
8.
Carefully separate the flow regulator
assembly from the switch assembly,
inlet connector and heater tank by
gently pulling apart.
9.
Make a note of the positions of all the
wiring on top of the heater tank.
10. Remove the screw that holds the
green earth wire to the thermal trip.
11. Ease the thermal trip away from the
heater tank.
Caution! Do not press printed disc
on the thermal trip as this will make
the component unserviceable.
12. Remove the screw that holds the two
blue wires to the top of the heater tank.
13. Refit the components in reverse order.
Make sure that the electrical wires and
'O' seals are installed in the correct
positions.
Inlet
Connector
Flow Regulator
Assembly
38
Switch
Assembly
Heater
Tank
Thermal
Trip
Green Earth
Wire