Configuration Of The Radio Modules Via The Web Interface; Configuration Via The Wavenet Monitor And Toolbox Software - Webdyn WebdynRF Installation Manual

Concentrator dedicated to smart metering and energy management
Table of Contents

Advertisement

Configuration of the radio modules via the Web interface

8.6.1
Each module is configured as follows:
Name
Address
Label
Type
Mode
Nb Input
Schedule
Repeaters
The Wavenis address may be entered in its hexadecimal form (12 digits) or in its
decimal form (15 digits, with an optional hyphen after the 5th and 7th figures).
The repeaters must be entered from the gateway to the module.
The modules associated with the same schedule are read in the order configured.
A request for a given module is repeated up to three times if necessary.

Configuration via the Wavenet Monitor and Toolbox software

8.6.2
The stages below explain how you can build your Wavenis network by using the
gateway as a Waveport with the Wavenet Monitor configuration tool and importing
the configuration file from this Coronis tool into the gateway.
WebdynRF – Installation Manual - Version 1.0
Wavenis address
Name of the module (for information purposes only)
Type of module
Reading mode (immediate, datalog)
Number of module inputs
Schedule's unique ID used for the module reading (see
8.5)
List of the radio addresses of the repeaters
Description