Dual Installation; Electrical - Sub-Zero BI-42UFDID/O Installation Manual

Hide thumbs Also See for BI-42UFDID/O:
Table of Contents

Advertisement

Available languages

Available languages

SI T E P R E PA R AT I ON

Dual Installation

If two units are installed side by side, a dual installation kit
may be required. Installations without a custom filler strip
require a dual installation kit. If a dual installation kit is not
specified, a 2"
filler strip is recommended between units.
(51)
Dual installations without a filler strip can only be accom-
plished using two units with opposite hinges. Refer to the
illustrations below.
Dual installation kits are available through an authorized
Sub-Zero dealer. For local dealer information, visit the find a
showroom section of our website, subzero.com. For ques-
tions regarding the installation, call Sub-Zero customer care
at 800-222-7820.
WITHOUT FILLER STRIP
Opposite hinges.
|
8
Sub-Zero Customer Care 800.222.7820
FILLER STRIP
Same side hinges.

Electrical

Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit, ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause inter-
ruption of operation.
E L E C T R I C AL R E Q U I R E M E N T S
Electrical Supply
Service
Receptacle
CAUTION
The outlet must be checked by a qualified electrician to
be sure that it is wired with the correct polarity. Verify
that the outlet is properly grounded.
WARNING
Do not use an extension cord, two-prong adapter or
remove the power cord ground prong.
7"
E
(178)
6"
(152)
1
75
/
"
2
(1918)
FROM FLOOR
RIGHT SIDE
OF OPENING
Electrical supply location.
115 VAC, 60 Hz
15 amp
3-prong grounding-type