5.1.4 Device (RPC, UPS, EMD) Mode

This mode configures the selected serial port to communicate with a serial controlled Uninterruptable Power Supply (UPS), Remote Power
Controller/Power Distribution Unit (RPC) or Environmental Monitoring Device (EMD).
Figure 5-10. Device settings screen.
Select the desired Device Type (UPS, RPC or EMD)
Proceed to the appropriate device configuration page (Serial & Network: UPS Connections, RPC Connection or Environmental) as detailed in
Chapter 8—Power Management.

5.1.5 Terminal Server Mode

Select Terminal Server Mode and the Terminal Type (vt220, vt102, vt100, Linux, or ANSI) to enable a getty on the selected serial port.
Figure 5-11. Terminal server settings screen.
The getty will then configure the port and wait for a connection to be made. An active connection on a serial device is usually indicated by
the Data Carrier Detect (DCD) pin on the serial device being raised. When a connection is detected, the getty program issues a login:
prompt, and then invokes the login program to handle the actual system login.
NOTE: Selecting Terminal Server mode will disable Port Manager for that serial port, so data is no longer logged for alerts, etc.

5.1.6 Serial Bridging Mode

With serial bridging, the serial data on a nominated serial port on one console server is encapsulated into network packets and then
transported over a network to a second console server. It is then represented on its serial port again as serial data. The two console servers
effectively act as a virtual serial cable over an IP network.
One console server is configured as the Server. Set the Server serial port to be bridged in Console Server mode with either RFC2217 or RAW
enabled (as described in Chapter 5.1.2—Console Server Mode).
For the Client console server, the serial port to bridge must be set in Bridging Mode: