magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or a defective motor IC drive on the main PCB).
Rotating gobo-wheel error:
The gobo-wheel is not located in the default position after start-up or after a reset
command. This message will appear after a fixture reset if the gobo wheel's
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or a defective motor IC drive on the main PCB).
Rotating gobo indexing error:
The gobo is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the gobo positioning magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
Fix Gobo-wheel error:
This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
drive circuit on the main PCB). The fix gobo wheel is not located in the default position
after the reset.
Prism Rotation error:
This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The Prism wheel is not located in the default position
after the reset.
Focus-error:
This message will appear after the reset of the fixture and if the magnetic indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The focus motor is not located in the default position after