been replaced, otherwise you risk damage to the retina and expose to UV
radiation!
When replacing an old lamp, always be sure to replace with an approved
replacement. In this case a Philips MSD Platinum 15R lamp is required. Be
sure the replacement lamp meets or exceeds the original lamp specifications,
failure to do so may damage the fixture and void the manufactures warranty.
Be sure to follow all the lamp handling procedures included with the new
lamp. Never handle the new lamp with your bare hands as the oils from your
skin may damage the lamp and cause premature lamp failure.
Installation Procedure:
1. Set the fixture on a flat surface and remove the two screws marked "A" and "B".
2. Remove the cover plate to access the lamp.
3. Gently remove the old lamp by grasping the ceramic socket base and twisting it
slightly in counter-clockwise direction until it becomes free.
4. Once the lamp becomes free, grasp the ceramic socket and gently pull away
from the lamp.
5. Insert the new lamp securely. The lamp will only seat one way, please be sure to
insert the lamp in the same position as the old one. Before reassembling the unit,
be sure the new lamp is securely seated in the lamp socket. Always be sure to
only use specified lamp types! (Philips MSD Platinum 5R).
6. Once the lamp has been inserted and secured into the socket, follow the lamp
optimization instructions outlined below, then lock the lamp cover back in to place
by securing screws "A" and "B".
7. Be sure to reset the lamp run time in the system menu to avoid any possibly of
the lamp protection circuitry from accidently shutting off the lamp during normal
operation.
Platinum Beam 15R™