Elation PLATINUM BEAM 15R Manual page 30

Hide thumbs Also See for PLATINUM BEAM 15R:
Table of Contents

Advertisement

Movement Speed – This function changes the speed function of the Pan and Tilt motors.
Use this function intergrading Platinum Beam 5Rinto lighting rigs that includes original
Design Spot 250s. There are 3 different mode variations;
Speed 1 (Default): Slower than the original Design Spot 250 for smoother,
precise movements.
Speed 2: Pan and Tilt speeds are identical to the first generation Design Spot
250.
Speed 3: includes a faster Pan speed. Pan speed is 0.5 seconds faster than original
DS-250. Tilt speed will be the same as speed 2.
Mic Sensitivity – This function makes the internal microphone more or less sensitive to
sound. This function only works in conjunction with the sound active modes. The default
setting is 70% and setting range from 0% to 99%.
Hibernation – When activated, this function will automatically put the fixture in power
stand-by mode after a defined period of time of no DMX activity. This prevents the fixture
form expending power for extended periods in the event the fixture has been left on
accidently. In stand-by mode the lamp and all motors will power down if no DMX signal is
sent to the fixture for a period of 15 minutes (default, can be user defined). The fixture will
automatically reset and return to normal operation once a DMX signal is sensed.
V1.0 Mode – This function should only be activated when intergrading first generation
Platinum Spots (Ver 1.0) with second generation or higher Platinum Spots (Ver 1.1 or
higher). This function will match the gobo rotation speed to that of the first generation
fixtures. When this function is not activated the gobo change will not match between the
different generation fixtures.
9.4.2 Fans Control - This function is used to change the functionality of the internal cooling
fans. The available selections are: 1) "AUTO" – The fans will automatically switch between
low and high speeds depending on the internal operating temperature. 2) "HIGH" – The fans
will run in high-speed mode regardless of operating temperature. 3) "LOW" – The fans will
remain in low speeds regardless of internal operating temperature.
9.4.3 Display Settings
Shutoff Time - The display is designed to turn off during normal operation to avoid excessive