Page 2
Elation Professional USA | 6122 S. Eastern Ave. | Los Angeles, CA. 90040 323-582-3322 | 323-832-9142 fax | www.elationlighting.com | info@elationlighting.com Elation Professional B.V.
C O N T E N T S General Information Limited Warranty Safety Instructions and Guidelines Overview Installation Optional Snoot Installation System Menu DMX Channel Functions And Values Error Codes Cleaning and Maintenance Technical Specifications Dimensional Drawings Optional Accessories FUZE WASH Z120™ User Manual...
Please do not discard the shipping carton in the trash. Please recycle whenever possible. BOX CONTENTS (1) Omega Bracket (1) Locking Power Cable FUZE WASH Z120™ User Manual...
Page 5
You may also visit us on the web at www.elationlighting.com for any comments or suggestions. For service related issue please contact Elation Professional®. ELATION SERVICE USA - Monday - Friday 8:00am to 5:00pm PST Voice: 323-582-3322 Fax: 323-832-9142 E-mail: support@elationlighting.com...
The sole responsibility of Elation Professional® under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional®. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect.
INDOOR / DRY LOCATIONS USE ONLY! DO NOT EXPOSE FIXTURE TO RAIN AND MOISTURE! NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! RETINA INJURY RISK - MAY INDUCE BLINDNESS! SENSITIVE PERSONS MAY SUFFER AN EPILEPTIC SHOCK! FUZE WASH Z120™ User Manual...
Page 8
• Consistent operational breaks will ensure the fixture will function properly for many years to come. • Use the original packaging and materials to transport the fixture in for service. FUZE WASH Z120™ User Manual...
10 times the weight of the fixture. • Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable. • Never stand directly below the device when mounting, removing or servicing. FUZE WASH Z120™ User Manual...
Page 11
M10 screw fitted through the center hole of the Omega Bracket. Be sure to attach an appropriate Safety Cable (not included) to the fixture using the safety cable rigging point integrated in the base assembly. FUZE WASH Z120™ User Manual...
Page 12
If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury. Fixture is fully operational in the specific mounting positions illustrated below. FUZE WASH Z120™ User Manual...
Page 13
Max number of FUZE WASH Z120 IP™ units power linked together: 6 units @120V | 12 units @240V NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO FUZE WASH Z120™! POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY! ALWAYS CHECK MAX AMP OUT RATING PRINTED ON THE REAR CONNECTION PANEL!
1. Place fixture on a flat surface and make sure it’s powered OFF. 2. Insert Snoot into fixture head and secure using screws provided. (See image below) Make sure not to over tighten screws to prevent any issues. FUZE WASH Z120™ User Manual...
1 minute from the last button press. INFORMATION DISPLAYED DURING INITIAL POWER ON When the fixture is initially powered ON, the display shows the following information: Software Update Motor Reset Please Wait... Please Wait... FUZE WASH Z120™ User Manual...
Page 16
900, 1000, 1100, 1200, 1300, 1400, 1500, Frequency (Hz) Frequency Response 2500, 4000, 5000, 10k, 15k, 20k, 25k Gamma 2.0, 2.2, 2.4, 2.6, 2.8 Gamma correction DFSE ON / OFF Restore Factory Settings CONTINUED ON NEXT PAGE FUZE WASH Z120™ User Manual...
Page 17
Program In Loop Program Test Program Program 9 Save and Exit Step 01-64 Edit Scene 001 Pan, Tilt, … ~Edit Scene 250 Fade Time Edit Sce. Scene Time Input By Outside Sce. Input XX~XX Scene Input FUZE WASH Z120™ User Manual...
Page 18
(8), and then set Channel 3 to a value of (164). (256+164=420) 5. After setting Channel 3 to the desired DMX address value, wait for approximately 20 seconds for the fixture to complete the address reset function. FUZE WASH Z120™ User Manual...
Page 19
Because calibration is an extremely delicate procedure, instructions on performing this action are left out of this manual. For a first-time calibrator, please contact our customer support team for step-by-step instructions. FUZE WASH Z120™ User Manual...
160-191 LED ON 192-223 Random Strobe Effect SLOW to FAST 224-255 LED ON 0-255 0 to 100% GREEN 0-255 0 to 100% BLUE 0-255 0 to 100% 0-255 0-100% SATURATION 0-255 0-100% INTENSITY 0-255 0-100% FUZE WASH Z120™ User Manual...
Page 21
251-255 Gradient Effect AUTO PROGRAM SPEED 0-255 Slow to Fast AUTO PROGRAM FADE 0-255 0-100% DIMMING MODES 0-20 STANDARD 21-40 STAGE 41-60 61-80 ARCHITECTURAL 81-100 THEATRE 101-255 Default to Unit Setting CONTINUED ON NEXT PAGE FUZE WASH Z120™ User Manual...
Page 23
15000 Hz 20000 Hz 25000 Hz Disable LED Refresh Rate 80-84 All Motor Reset 85-99 No Function 100-119 Internal Program 1 (scene1~8 of EEPROM) 120-139 Internal Program 2 (scene9~16 of EEPROM) CONTINUED ON NEXT PAGE FUZE WASH Z120™ User Manual...
Page 24
180-199 Internal Program 5 (scene33~40 of EEPROM) from prev from prev prev prev page) page) 200-219 Internal Program 6 (scene41~48 of EEPROM) page) page) 220-239 Internal Program 7 (scene49~56 of EEPROM) 240-255 No Function FUZE WASH Z120™ User Manual...
(sensor failed or magnet is missing) or there is a motor ZOOM Er failure (defective motor or a defective motor IC drive on the main PCB). This error may also be displayed if the head/yoke was blocked during a reset function. FUZE WASH Z120™ User Manual...
Regular inspections are recommended to insure proper function and extended life. There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer.
5F to 113°F (-15°C to 45°C) BTU/hr (+/- 10%) 535.37 APPROVALS / RATINGS CE | IP30 | Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. FUZE WASH Z120™ User Manual...
. e l a t i o n l i g h t i n g . c o m DIMENSIONAL DRAWINGS Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. FUZE WASH Z120™ User Manual...
Page 29
. e l a t i o n l i g h t i n g . c o m DIMENSIONAL DRAWINGS - Optional Snoot Installed Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. FUZE WASH Z120™ User Manual...
Need help?
Do you have a question about the FUZE WASH Z120 and is the answer not in the manual?
Questions and answers