Elation PLATINUM BEAM 15R Manual page 27

Hide thumbs Also See for PLATINUM BEAM 15R:
Table of Contents

Advertisement

Total Run Time
This function tracks the total running time of the fixture from the very first start-up. Where
"XXXX "represents the total number of running hours. This time is none destructive and
will remain in the fixtures memory indefinitely.
Last Run Hours
This function tracks a cycle run time. Use this function to keep track of rental period, or to
note the time from the last service. This setting can be reset at any time, see
"L-Timer Password."
Lamp Hours. This function tracks the total number of lamp running hours. Where "XXXX"
represents the number of hours the lamp has been running. This counter should be reset
after every lamp change.
Lamp Off Time
This function displays the running time of the lamp from the last power on. The display
shows "XXXX", where "XXXX" represents the number of hours the lamp has been
running since it was last struck. This counter is automatically reset after every power-on.
Timer Password
Use this function to enter the "Clear Last Run" password. Password is "038"
Clear Last Run
This function will allow the "Last Run Hours" function be cleared and reset.
L-Timer Password
Use this function to enter the "Clear Lamp Time" password. Password is "038"
Clear Lamp Time
This function resets the lamp "ON" time to zero. Please reset the lamp "ON" time at every
lamp replacement. This procedure tracks the lamp running time so the lamp can be
replaced at the end of it's recommended duty cycle.
• Select "Clear lamp time" in the system menu.
• The LCD will display "ON" or "OFF." Were "ON" will reset the lamp time.
• Press enter to confirm.
• Press the Mode/Esc-button to return to the main menu.
9.2.2.
Temperature Info.
This function will detail the internal head temperature in either Celsius or Fahrenheit.