HP ProLiant BL40p Setup And Installation Manual page 71

Server blade
Hide thumbs Also See for ProLiant BL40p:
Table of Contents

Advertisement

Configuring and Deploying Server Blades
To navigate RBSU, use the following keys:
To access RBSU, use the iLO Remote Console and press the F9 key when
prompted during power up.
To navigate the menu system, use the arrow keys.
To make selections, press the Enter key.
RBSU automatically saves settings when you press the Enter key. The utility does
not prompt you for confirmation of settings before you exit the utility. To change a
selected setting, you must select a different setting and press the Enter key.
Table 2-2 contains the default settings for options in primary RBSU menus.
Table 2-2: RBSU Default Settings
Menu/Option
System Options
OS Selection
Serial Number
Embedded NIC Port 1 PXE Support
Standard Boot Order (IPL)
Automatic Server Recovery
ASR Status
ASR Timeout
Thermal Shutdown
Server Passwords
Set Power-On Password
Set Admin Password
* The default boot order is CD-ROM drive, diskette drive, hard
drive, and network, respectively.
2-22
Default Setting
Windows 2000
Enabled
*
Enabled
10 minutes
Enabled
Disabled
Disabled
HP ProLiant BL40p Server Blade Setup and Installation Guide
continued