LEDs and Switches
Table E-3: Hot-Plug SCSI Hard Drive LED Status Combinations
(1) Activity
(2) Online
On
Off
On
Flashing
Flashing
Flashing
Off
Off
Off
Off
E-6
(3) Fault
Means
Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is being accessed and is not configured as
part of an array.
Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is rebuilding or undergoing capacity
expansion.
Flashing
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is part of an array being selected by the Array
Configuration Utility.
-or-
The Options ROMPaq is upgrading the drive.
Off
OK to replace the drive online if a predictive failure alert
is received and the drive is attached to an array
controller.
The drive is not configured as part of an array.
-or-
If this drive is part of an array, a powered-on controller
is not accessing the drive.
-or-
The drive is configured as an online spare.
On
OK to replace the drive online.
The drive has failed and has been placed offline.
HP ProLiant BL40p Server Blade Setup and Installation Guide