Removing The Feature Board, The Power Supply Board, And The Inline Fuse - Whirlpool Polara GR556LRK Service Manual

Refrigerated range
Table of Contents

Advertisement

REMOVING THE FEATURE BOARD, THE POWER
SUPPLY BOARD, AND THE INLINE FUSE
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
NOTE: Sharp edges may be present.
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Remove the right side panel from the
refrigerated range (see steps 4a through
4e on page 4-11 for the procedure).
Feature Board Inline Fuse
Power Supply Board
(Viewed From Right Side Of Unit)
3.
4.
5.
Inline Fuse Connector
Connector
4-17
To remove the feature board:
a) Disconnect the wire connectors at
P2300 and P2301.
b) Remove the mounting screw, and slide
the board to the left to unhook it from
the locking tabs.
Feature Board
P2300
P2301
Screw P2
Power Supply Board
To remove the power supply board:
a) Disconnect the wire connectors at P1
and P2.
b) Remove the two mounting screws.
To remove the inline fuse, unlatch the
connector catches from the tabs, and pull
out on the inline fuse connector.
Screw
P1
Screw
Catch
Tab