Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
BIMETALS (N.C.)
Refer to page 4-33 for the procedure for servic-
ing the bimetals.
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter leads to the bimetal
connector pins. The meter should indicate
a closed circuit (0 Ω). If the reading indi-
cates an open (infinite) circuit, replace the
bimetals.
IMPORTANT:The bimetal marked (F36-18F)
must be mounted below the other bimetal. The
bimetals will be replaced as an assembly.
Lower Bimetal (F36-18F)
WARNING
Electrical Shock Hazard
SINGLE ELEMENT INFINITE
SWITCHES (RF, RR, & LR)
L1
L2
H2
Refer to page 4-2 for the procedure for servic-
ing a single element infinite switch.
NOTE: Refer to the Tech Sheet Wiring Dia-
gram that is supplied with the unit to determine
the wiring for the infinite switch you are servic-
ing.
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Turn the appropriate infinite switch to the
On position.
4.
Touch the ohmmeter test leads to termi-
nals L1 and P. The meter should indicate
continuity (0 Ω).
5.
Touch the ohmmeter test leads to termi-
nals L1 and H1. The meter should indicate
continuity (0 Ω).
6.
Touch the ohmmeter test leads to termi-
nals L2 and H2. The meter should indicate
continuity (0 Ω).
5-5
P
H1
P
L1
L2
H1
H2