Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
DUAL ELEMENT INFINITE
SWITCH (LF)
4
S2
4a
S1
S2
4a
4
Refer to page 4-2 for the procedure for servic-
ing the dual element infinite switch.
NOTE: Refer to the Tech Sheet Wiring Dia-
gram that is supplied with the unit to determine
the wiring for the infinite switch you are servic-
ing.
Electrical Shock Hazard
P1
2
P2
S1
P1
P2
2
5-6
WARNING
1.
Unplug the refrigerated range or discon-
nect the power.
2.
Set the ohmmeter to the R X 1 scale.
3.
Turn the dual element infinite switch to the
"single" position.
4.
Touch the ohmmeter test leads to the
following terminals. The meter should in-
dicate continuity (0 Ω):
a) S1 - S2
b) P1 - 2
c) P2 - 4
5.
Set the ohmmeter to the R X 1K scale.
6.
Touch the ohmmeter test leads to termi-
nals 2 and 4. The meter should indicate
approximately 5200 Ω.
7.
Turn the dual element infinite switch to the
"dual" position.
8.
Set the ohmmeter to the R X 1 scale.
9.
Touch the ohmmeter test leads to the
following terminals. The meter should in-
dicate continuity (0 Ω):
a) S1 - S2
b) P1 - 2
c) P2 - 4
d) P2 - 4a
10. Set the ohmmeter to the R X 1K scale.
11. Touch the ohmmeter test leads to termi-
nals 2 and 4. The meter should indicate
approximately 5200 Ω.