7.4.6 Remove closing handle
•
Close brewing unit.
•
Hold closing handle (9) in one hand while loosening both screws (41, torx head
TX 20)
•
Pull off closing handle from lever arms.
7.4.7 Remove cable cover
•
Open 2 latches one after another with disassembly tool.
•
Lift cable cover (6) and release remaining 2 latches at the front with a screwdriver if
necessary.
41
9
6
R E P A I R S
Pixie service manual
Take care, that both
lever arms stay in
horizontal position.
Otherwise, disassembling
of housing right is impossi-
ble.
Bottom view
Latches will break if
not unlocked very
carefully!
37