Assembly checkpoints
•
Only use the original spare part for replacing the country-specific power cord.
•
Adjust power cord lenght to customer's demand.
•
Connect the insulated faston receptacles of neutral (N) and live (L) power cord wires
like shown above.
7.4.4 Remove water guiding
8
•
Open brewing unit with closing handle (9).
•
At first push up water guiding (8) and simultaneously pull out latch at the bottom with
the help of a screwdriver.
•
Then push down again and remove water guiding (see detail).
Protective Earth
Live (L)
Neutral (N)
R E P A I R S
9
Pixie service manual