1
G E N E R A L S A F E T Y N O T E S
Risk of fatal electrical shock and fire!
Mains voltage inside the coffee machine.
Unplug appliance before cleaning.
Never clean wet or immerse plug, cord or appliance in any fluid.
Disconnect the mains plug before disassembly - the appliance must
be free of voltage.
As an additional safety measure, the use of a residual current device (RCD), also called
a ground fault circuit interrupter (GFCI), in the repair centre is highly recommended.
1) RCD protected socket-outlet
2) Plug-in RCD unit
Danger of burns!
Hot parts and water under pressure inside the coffee machine
(particularly in the thermoblock).
Let coffee machine cool down before cleaning or disassembly.
G E N E R A L S A F E T Y N O T E S
1
R E S E T
2
T E S T
3
R E S E T
4
T E S T
3) GFCI socket
4) Plug-in GFCI
Pixie service manual
This device does
not protect against
electrical shock due to
contact with both circuit
conductors.
Example illustrations
of typical devices.
Use a GFCI with a trip
level of 4 - 6 mA (USA)
resp. a RCD with a trip
level of 15 - 30 mA (Europe).
A trip level above 30 mA
provides only very limited
protection against harm
from an electric shock.