The strain relief
clamp is under ten-
sion. Therefore, hold
down the strain relief clamp
with your finger when
unlatching it.
34
R E P A I R S
•
Unlatch strain relief clamp (39) with a 2 mm flat blade screwdriver.
•
Disconnect ground wire (green/yellow) from thermoblock with pointed pliers.
•
Lever out both insulated faston receptacles from electronic control board with a
screwdriver.
•
Before removing the power cord (40), check if excessive cable length is retained in
right housing.
Pixie service manual
39
40