The pressure gauge
adapter must sit
firmly in the capsule
bay.
70
F U N C T I O N T E S T S
8.4.1 Preparations
1
1) Remove maintenace unit.
2) Remove right side panel (see "General
disassembly" on page 31).
6
5
7
5) Mount pressure gauge adapter (refer
to page 67).
6) Connect pressure hose to pressure
tester.
7) Place a receptacle under the drain
hose of the pressure tester.
Pixie service manual
4
2
3) Fill and insert water tank.
4) Open closing handle.
8) Connect mains cable.
9) Switch on coffee machine.
10) After heating up, press the "large cup"
button.
3
9
10