The pressure gauge
adapter must sit
firmly in the capsule
bay.
68
F U N C T I O N T E S T S
8.3
Measure flow rate
2
1) Fill and insert water tank.
2) Open closing handle.
4
5
4) Connect pressure hose to pressure
tester.
5) Place a measuring cup under the
drain hose of the pressure tester.
Pixie service manual
1
3) Mount pressure gauge adapter (refer
to page 67).
6) Switch on coffee machine.
7) After heating up, press the "large cup"
button.
8) Open the valve until water begins to
flow.
3
6
8
7