4.8 TRANSDUCER SETUP

This menu allows you to calibrate the speed through the water, water temperature and the
keel/prop offset of the transducer. Select the Fish Finder page then follow the procedure
below:
1. Tap anywhere on the screen.
2. Tap on the
3. Tap on TRANSDUCER SETUP. A popup window will be shown with the available
options KEEL OFFSET, CALIBRATE WATER SPEED, CALIBRATE WATER TEMP,
CALIBRATE AUX TEMP, and SET DEFAULTS. See the following paragraphs.
4. Tap on the desired item.
5. When the item you want has been selected, press the

4.8.0 KEEL OFFSET

The keel offset can be set to cause the Fish Finder to display an offset depth below the keel
or the actual water depth from the surface. To setup to show the depth below the keel, enter
a negative depth value or a positive depth to show offset from the transducers face to the
water surface.

4.8.1 CALIBRATE WATER SPEED

Used to calibrate the Water Speed readings from the transducer. Adjustment can be made
from -10% to +10%.

4.8.2 CALIBRATE WATER TEMP

Used to calibration on the Water Temperature sensor in the transducer.

4.8.3 CALIBRATE AUX TEMP

Allows the calibration of the Aux Temperature sensor connected to the Optional Connection
wires.
CPN and FF525 Operation Manual
Soft Key.
key to exit.
Page 25