Cisco 800 Series Hardware Installation Manual page 269

800 series integrated services router
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Appendix A
Technical Specifications
Table A-3
Cisco 819 ISR Specifications
Description
Physical Characteristics
Dimensions (H x W x D)
Weight
Maximum Power
Consumption
Environmental Operating Ranges
Operating Temperature and
Altitude
Humidity
Environmental Tests
Ingress Protection Rating
Humidity
Pollution
Military Standard
Vibration and Shock
(Railway Vehicles)
Heavy-Duty Vehicle
Applications
Certifications
Hardened Design
Specification
(Cisco 819HG and Cisco
819HG-4G ISRs)
1.73 x 7.7 x 8.1 in
(44 x 196 x 206 mm)
3.3 lb (1.5 kg)
11 W
–13 to 140°F
(–25 to 60°C)
Derate max operating temperature 1.5°C per 1000 feet above 5000 ft
10,000 ft maximum
Maximum 95%
non-condensing RH
IP 41 per IEC 60529 for
Vertical Falling Water,
Pollution Degree 3
Non-condensing Relative Humidity: 5% to 95%
Pollution 3 for Dust
MIL-STD-810G Method 514.6: Procedure 1 Category 4, Secured Cargo - Common Carrier
MIL-STD-810G Method 514.6: Procedure 1 Category 20, Ground Vehicles
MIL-STD-810G Method 516.6. Procedure 1, Functional Shock
MIL-STD-810G Method 516.6. Procedure 5, Crash Hazard
MIL-STD-810G Method 516.6. Procedure 6, Bench Handling
EN61373 Functional Random Vibe - Category 1, Class B
EN61373 Simulated Non-op Long-life Vibe - Category 1, Class B
EN61373 Non-op Shock, Class B
SAE J1455 Operating Random Vibe, Cab Mounted Truck
SAE J1455 Operating Sinusoidal Vibe, Category 3
SAE J1455 Non-operating Sinusoidal Vibe, Category 3
SAE J1455 Handling Drop Test
Non-Hardened Design
Specifications
(Cisco 819G and Cisco
819G-4G ISRs)
1.67 x 7.7 x 7.2 in
(42 x 196 x 183 mm)
2.3 lb (1.0 kg)
32 to 104°F
(0 to 40°C)
Maximum 85%
non-condensing RH
IP 20 per IEC 60529
Cisco Integrated Services Router Hardware Installation Guide
Cisco 810 Series
Hardened Design Specifications
(C819HGW and C819HWD ISRs)
1.73 x 7.7 x 9.0 in
(44 x 196 x 229 mm)
3.4 lb (1.54 kg)
20 W
–13 to 140°F
(–25 to 60°C)
Maximum 95% non-condensing
RH
IP 41 per IEC 60529 for Vertical
Falling Water, Pollution Degree 3
A-5

Hide quick links:

Advertisement

Table of Contents
loading