INJECTOR TABLE

Type of gas used
NATURAL GAS
(Methane) G20
LIQUID PETROLEUM GAS
(Butane) G30
Type of gas used
G20 20 mbar
G30 mbar
ELECTRICAL POWER SUPPLY: 220 V ~ 60 Hz
NB: Cooking times and temperatures are approximate.
CLASSES OF APPLIANCES
The cooking appliances described on this product sheet belong to the
following installation classes:
• Class 1: non-flush-mounted cooking appliance;
• Class 2 - subclass 1: cooking appliance flush-mounted between two
units, consisting of a single unit, but which can also be installed so that the
side panels are accessible.
Type of
Injector
burner
marking
rapid
115
semi-rapid
97
auxiliary
72
85
rapid
65
semi-rapid
Appliance model
1R - 2 SR - 1 AUX + oven
1R - 2 SR - 1 AUX + oven
Injector
Rated
marking
consumption
3.0
236 l/h
1.75
167 l/h
1.0
95 l/h
3.0
236 l/h
1.75
167 l/h
Total nominal
Total nominal
consumption
heating power kW
7.5
665 l/h
7.5
545 g/h
CATEGORY P/B3H2II
Gas pressure mbar
Reduced heat
capacity kW
min
0.70
17
0.495
0.30
0.85 0.65
25
Air necessary (m
combustion of 1 m
9.52
30.94
nominal
max.
25
20
35
30
3
) for the
3
of gas