Contents Contents Waldorf Gas Range Convection Oven RN(L)8910GC Gas Range Convection Oven - 4 Burner, 900mm Wide. Introduction ....................2 Specification ....................3 Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection Electrical Supply Requirements Dimensions ....................6 Installation ....................
Introduction We are confident that you will be delighted with your WALDORF Gas Range Convection Oven, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Waldorf appliance, there are two important things you can do.
Specifications Model Numbers Covered in this Specification RN[1]8910GC [2] 4 Open Burners + Turbofan Convection Oven. NOTE: [1] - Back Options; - Standard Models. - Low Back Models. [2] - Open Burner Options; - With Flame Failure Protection. - With Pilot and Flame Failure Protection. General A heavy duty, general purpose gas convection oven - range created for compact modular kitchens.
Specifications - All Other Markets: Natural Gas Town Gas (**) Input Rate (N.H.G.C.) 28MJ/hr 28MJ/hr - each Open Burner - Oven 30 MJ/hr 30 MJ/hr Supply Pressure 1.13 - 3.40kPa 0.75 - 1.50kPa Burner Operating Pressure (*) 0.95kPa 0.63 Pa Gas Connection See ‘Gas Connection’...
Waldorf Gas Range Convection Ovens are designed to provide years of satisfactory service, and correct installation is essential to achieve the best performance, efficiency and trouble-free operation.
Installation Clearances NOTE: Only non-combustible materials can be used in close proximity to this appliance. Combustible Surface Non Combustible Surface Left / Right hand side 250mm (*) Rear 100mm * Side clearances can be 50mm when adjacent surface is at least 100mm below cooking surface. Assembly All Models are delivered completely assembled.
Installation Regulator connections are " BSP female. Connection to appliance is " BSP male. (Refer to ‘Specifications’ section for gas supply location dimensions). NOTE: A Manual Isolation Valve must be fitted to individual appliance supply line. Correctly locate appliance into its final operating position and using a spirit level, adjust legs so appliance is level and at correct height.
/ operator. Waldorf appliances have been designed to provide simplicity of operation and 100% safety protection. Improper operation is almost impossible, however bad operation practices can reduce the life of the appliance and produce a poor quality product.
Operation Open Burners Open Burners ('F' - Flame Failure Option) NOTE: Only cooking pans from size Ø 150mm to Ø 420mm are suitable fo use on these open Lighting the Open Burners burners. Flame Failure Protection is incorporated for each burner by way of a thermo-electric system which Flame Failure Option (F-Models) will shut off gas supply to that burner in the event that burner goes out, so that un-burnt gas is not expelled.
Operation Oven Pilot Ignition ! IMPORTANT Pilot Burner DO NOT USE aluminium foil or trays directly on cast iron Inspection Covers sole plate(s). NEVER block or cover openings on each side of sole plate(s). This oven is fitted with a pilot as a standard option and flame failure protection, which is incorporated by way of a thermo- electric system for main burner.
Operation Oven ‘Shut-Down’ To ‘Shut Down’ oven, turn oven thermostat to ‘0’ position, oven main burners will go out. Turn gas control valve to 'OFF' position and this will extinguish pilot burner. (To relight pilot burner, refer to ‘Oven Pilot Ignition’ on previous page). Turn ‘OFF’...
Ensure that any detergent or cleaning material has been completely removed after each cleaning. To keep your Cooktop clean and operating at peak efficiency, follow the procedures shown overleaf:- RN8910GC - Cooktop Only, shown for reference Spill Tray Pot Stand...
Cleaning and Maintenance Open Burner Cleaning Oven Interior Cleaning 1. Remove pot stands, burner caps, burner bowls 1. Do not use wire brushes, steel wool or other abrasive materials to clean oven interior. and pot stand supports from top of cooktop. Wash with hot soapy water, using a soft 2.
Fault Finding This section provides an easy reference guide to the more common problems that may occur during the operation of your appliance. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this section covers the most common problems reported, you may encounter a problem not covered in this section.
Gas Conversion and Specifications Conversion Procedure Caution Ensure that the Appliance is isolated from the gas supply before commencing servicing. NOTE: These conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning the appliance. ...
Gas Conversion and Specifications Convection Oven Thermocouple Piezo Igniter Carry out the following:- Remove lower lintel at front of oven. Pilot Burner Main Burner Open oven door and remove sole plate(s). Loosen clamp bracket and remove main burner.
Page 22
Gas Conversion and Specifications Gas Type Identification Label On completion of gas conversion, replace gas type identification label located at:- - Rear of appliance, above gas connection. - Beside rating plate. Commissioning Before leaving the installation; Check all gas connections for leakage using soapy water or other gas detecting equipment. Warning O NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES Carry out a ‘Commissioning’...
Gas Conversion and Specifications Gas Specifications - Australia: Natural Gas LP Gas (Propane) Ø 2.45mm Ø 1.50mm Main Burner Injectors Open Burner 0.30 0.20 Pilot Burner ('PF' Option Only) Ø 2.60mm Ø 1.60mm Main Burner 0.35 0.23 Pilot Burner Oven Ø...
Page 24
Gas Conversion and Specifications - All Other Markets: Natural Gas Town Gas (**) Main Burner Ø 2.45mm Ø 4.50mm Open Burner Pilot Burner ('PF' Option Only) 0.30 0.60 Main Burner Ø 2.6mm Ø 5.0mm Pilot Burner 0.35 0.60 Oven Low Fire Ø...
Replacement Parts List Replacement Parts List IMPORTANT: Only genuine authorized replacement parts should be used for servicing and repair of this appliance. Instructions supplied with parts should be followed when replacing components. further information servicing instructions, contact your nearest authorized service branch (contact details are as shown on reverse of front cover of this manual).
Page 27
Gas Conversion and Specifications Gas Regulators Gas Regulators Gas Type Description Part No. Nat. Gas 228531 ¾” BSP F/F Convertible. Butane Town Gas 230185 ¾” BSP F/F Adjustable. Gas Conversion Kits Gas Type to Convert to Models Nat. Gas Butane Town Gas Nat.
Need help?
Do you have a question about the RN8910GC and is the answer not in the manual?
Questions and answers