Electrical Connection - Waldorf GP8910GE Installation And Operation Manual

Gas griddle range electric oven 800 series
Hide thumbs Also See for GP8910GE:
Table of Contents

Advertisement

Installation

Electrical Connection

NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY AN QUALIFIED
PERSON.
T
HIS APPLIANCE MUST BE EARTHED
QUALIFIED PERSON IN ORDER TO AVOID A HAZARD
Each appliance should be connected to an adequately protected power supply and isolation switch mounted
adjacent to, but not behind the appliance. This switch must be clearly marked and readily accessible in
case of fire.
1.
Check that the electricity supply is correct as shown
on the Rating Plate attached to the lower front
hand side of the front sill panel.
2.
The supply terminal connections are located at the
rear of the appliance. Refer to 'Electrical
Connections' in the 'Dimensions' section of the
manual.
3.
Open the oven door and remove the oven control
panel to allow connection access for the electrical
supply.
4.
Connect the mains supply to L1, L2 and L3
connection terminals. Refer to the 'Electrical
Supply Requirements' section for connection
details.
NOTE: This appliance can be converted from 3 Phase
to Single Phase supply by connecting the
single phase input to L1 and adding a bridge
wire
between
connections, (refer to Fig 3 opposite and the
information shown in the 'Electrical Supply
Requirements Table' in the 'Specifications'
Section).
Changing the supply from 3 phase to single phase will increase the electrical
current loading on the supply cable. Ensure that the supply cable used is of a
sufficient
size
for
Requirements' in the 'Specifications' section.
5.
Connect neutral and earth conductors to neutral stud and earth stud respectively.
6.
For all connections ensure that conductors are secure and appropriately terminated.
7.
Tighten the cable gland to secure against tension on the cable.
8.
Check that the polarity of each connection is correct to the mains connection terminals markings on
the appliance.
NOTE:
• This appliance must be earthed.
• Fixed wiring installations must incorporate an all-pole disconnection switch.
9.
Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs
so that the appliance is level and at the correct height.
10.
Connect the power supply to the appliance.
11.
Check that the electrical supply is within the input rating specification, refer to the 'Specifications'
section).
WARNING:
. I
F THE SUPPLY CORD IS DAMAGED
.
the
L1,
L2
and
C
AUTIO N
the
current
loading,
,
IT MUST BE REPLACED BY A SUITABLY
L3
P
:
refer
to
10
Add bridging
wires between
L1, L2 and L3.
Neutral supply
connection to N
Phase supply
connection to L1
N