  • Page 1: Electric Oven

    I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Gas Griddle Range Electric Oven GP8910GE GPL8910GE GP8910GEC GPL8910GEC GP8121GE...
  • Page 2 MANUFACTURED BY Moffat Limited Christchurch New Zealand INTERNATIONAL CONTACTS AUSTRALIA Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888 (fax) +61 (03) 9518 3833 Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281...
  • Page 3: Table Of Contents

    Contents Waldorf Gas Griddle Electric Oven Ranges GP(L)8910GE Gas Griddle Range Electric Static Oven - 900mm. GP(L)8910GEC Gas Griddle Range Electric Convection Oven - 900mm. GP(L)8121GE Gas Griddle Range Electric Static Oven - 1200mm. GP(L)8121GEC Gas Griddle Range Electric Convection Oven - 1200mm.
  • Page 4: Introduction

    We are confident that you will be delighted with your WALDORF GAS GRIDDLE RANGE ELECTRIC OVEN, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Waldorf appliance, there are two important things you can do.
  • Page 5: Specifications

    Specifications Model Numbers Covered in this Specification GP[1]8910GE Gas Griddle Range Static Electric Oven - 900mm. GP[1]8910GEC Gas Griddle Range Convection Electric Oven - 900mm. GP[1]8121GE Gas Griddle Range Static Electric Oven - 1200mm. GP[1]8121GEC Gas Griddle Range Convection Electric Oven - 1200mm.
  • Page 6: Gas Supply Requirements

    Specifications Gas Supply Requirements - Non CE Only (Australia / New Zealand): Natural Gas LP Gas (Propane) GP8910GE/GEC GP8121GE/GEC GP8910GE/GEC GP8121GE/GEC 80 MJ/hr 108 MJ/hr (102,364 80 MJ/hr 108 MJ/hr Input Rating (75,825 BTU) BTU) (75,825 BTU) (102,364 BTU) (N.H.G.C.) 1.13 - 3.40 kPa...
  • Page 7: Electrical Supply Requirements

    IT MUST BE REPLACED BY A SUITABLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD GP8910GE / GEC Electrical supply connection point is located at rear of appliance, approximately 80mm from right hand side, 466mm from rear and 150mm from floor.
  • Page 8: Dimensions

    Dimensions GP(L)8910GE / GEC GP(L)8121GE / GEC...
  • Page 9: Installation

    Waldorf Gas Griddle Range Electric Oven are designed to provide years of satisfactory service and correct installation is essential to achieve the best performance, efficiency and trouble-free operation.
  • Page 10: Clearances

    Installation Clearances NOTE: Only non-combustible materials can be used in close proximity to this appliance. Combustible Surface Non Combustible Surface Left / Right Hand Side 50mm Rear 50mm Assembly Caution  This appliance is for professional use and is only to be used by qualified persons.
  • Page 11: Gas Connection

    Installation Gas Connection NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON. It is essential that gas supply is correct for appliance to be installed and that adequate supply pressure and volume are available. The following checks should be made before installation:- a.
  • Page 12: Electrical Connection

    Installation Electrical Connection NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY A QUALIFIED PERSON. Warning HIS APPLIANCE MUST BE EARTHED F SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY A SUITABLY QUALIFIED PERSON IN ORDER TO AVOID A HAZARD Each appliance should be connected to an adequately protected power supply and isolation switch mounted adjacent to, but not behind appliance.
  • Page 13: Commissioning

    Installation Commissioning Before leaving the new installation; Check the following functions in accordance with operating instructions specified in ‘Operation’ section of this manual.  Light the Griddle Pilot Burner.  Light the Griddle Main Burner.  Check the Griddle Low Fire Operation. ...
  • Page 14: Operation

    / operator. Waldorf Gas Griddle Range Electric Oven have been designed to provide simplicity of operation and 100% safety protection. Improper operation is almost impossible, however bad operation practices can reduce the life of the appliance and produce a poor quality product.
  • Page 15: Lighting Griddle - Pilots

    Operation Lighting Griddle - Pilots Caution 235°C URFACE TEMPERATURE OF THE GRIDDLE PLATE CAN REACH OVER WHEN THE APPLIANCE IS OPERATED AT FULL SETTING These griddles are fitted with a pilot as a standard option and Flame Failure Protection, which is incorporated by way of a thermo-electric system for each main burner.
  • Page 16: Turning 'Off' Griddle Main Burner / Pilots

    Operation Turning 'Off' Griddle Main Burner / Pilot Turn gas control knob clockwise to pilot position. Main burner will extinguish and pilot burner will remain alight. To turn 'OFF' appliance completely, turn gas control knob fully clockwise to 'O' position, pilot burner will extinguish.
  • Page 17: Cleaning And Maintenance

    Cleaning and Maintenance General Caution Always turn ‘Off’ electrical and gas supply before cleaning. This appliance is not water proof. Do not use water jet spray to clean interior or exterior of this appliance. Clean the range regularly. A clean range looks better, will last longer and will perform better. Carbonised grease on the surface or on griddle plate will hinder transfer of heat from cooking surface to food.
  • Page 18: Daily Cleaning

    Cleaning and Maintenance Daily Cleaning Grease drawer should be checked and emptied frequently to prevent overflow and spillage. Remove grease drawer while still warm so that grease is in a liquid state. Empty any grease from drawer and wash thoroughly in same manner as any cooking utensil. Clean Control Panel with a damp cloth lightly moistened with a solution of mild detergent and water.
  • Page 19: Periodic Maintenance

    Cleaning and Maintenance Griddle - Chrome Plate Stainless Steel Surfaces a. Clean the exterior surfaces of the range with hot water, a mild detergent solution and a soft Caution scrubbing brush. Note that the gas control knobs are a push fit onto the gas control valve spindles and can be removed to allow cleaning of the front control panel.
  • Page 20: Fault Finding

    Fault Finding This section provides an easy reference guide to the more common problems that may occur during operation of your appliance. The fault finding guide in this section is intended to help you correct, or at least accurately diagnose problems with your equipment. Although this section covers the most common problems reported, you may encounter a problem not covered in this section.
  • Page 21: Wiring Schematics

    Wiring Schematics GP8910GE and GP8121GE...
  • Page 22 Wiring Schematics Wiring Diagram: GP8910GE GP8121GE...
  • Page 23 Wiring Schematics GP8910GEC and GP8121GEC...
  • Page 24 Wiring Schematics Wiring Diagram: GP8910GEC GP8121GEC...
  • Page 25: Gas Conversion And Specifications

    Gas Conversion and Specifications Conversion Procedure Caution Ensure Appliance is isolated from gas supply before commencing servicing. NOTE:  These conversions should only be carried out by qualified persons. All connections must be checked for leaks before re-commissioning the appliance. ...
  • Page 26: Gas Regulator

    Gas Conversion and Specifications Gas Regulator NOTE, Pin rotated for Natural Gas NOTE: Gas regulator supplied convertible between Natural Gas and LP Gas, but it’s outlet pressure is fixed ex-factory and NOTE, Pin rotated is NOT to be adjusted. for LPG Gas Type Labels On completion of gas conversion, replace gas type labels located at:- - Rear of unit, above gas connection.
  • Page 27: Gas Specifications

    Gas Conversion and Specifications Gas Specifications - Non CE Only (Australia / New Zealand): Natural Gas LP Gas (Propane) GP8910GE/GEC GP8121GE/GEC GP8910GE/GEC GP8121GE/GEC Main Burner 3.00mm 2.85mm 1.80mm 1.70mm Pilot Burner 0.41 0.25 Griddle Low Fire Adjustment 1 full turn counter clockwise from the Fully ‘IN’ position...
  • Page 28: Replacement Parts List

    229885 Thermocouple Interruped - Leaded (If Overtemp Fitted). 019218 Thermocouple (If no Overtemp Fitted). 032300 Main Injector (Nat Gas) 3.00mm (GP8910GE / GEC). 032285 Main Injector (Nat Gas) 2.85mm (GP8121GE / GEC). 032180 Main Injector (LPG) 1.80mm (GP8910GE / GEC).
  • Page 29 228804 1200mm Plinth Kit (1200mm Range). Gas Conversion Kits Gas Type to Convert to: Models Australia / New Zealand Only UK Only Nat. Gas Nat. Gas GP8910GE / GEC 232033 232032 232033 232032 GP8121GE / GEC 232037 232036 232037 232036...

Table of Contents