40
Wireless Wall Controller Installation (Optional) (cont.)
Wiring diagram (switch leg wiring not available)
WARNING: Ensure power is disconnected at the fuse/breaker distribution panel before wiring the wall controller and fan!
If switch leg wiring is not possible, secure the end of the red wire on the wall controller with a customer-supplied wire nut as shown.
Power Supply
PE/GROUND
See page 29 for
L2/AC NEUTRAL
specifications and
L1/AC LINE
wire colors.
Can be different AC circuits,
but this is not recommended.
PE/GROUND
110–240 VAC 1
Φ
L2/AC NEUTRAL
50/60Hz, 0.1A
L1/AC LINE

5. Mount the wall controller

Mount the wall controller with the two (2) provided 6-32 x 7/8" screws (a) in a location within 50 ft (15.2 m) of the fan (or the first fan if
you are installing multiple linked fans). Do not overtighten the screws. Install the customer-supplied wall plate using the screws provided
with the wall plate (b). Note: Big Ass Fans recommends using a Decora
1.65" (4.19 cm)

6. Test the fan(s)

Apply AC power, and then turn on the fan(s) using the wall controller to test the DIP switch address. If the wall controller does not
operate the fan(s) due to interference with other radio frequency devices, select a different address on the wall controller, and then set
the matching address on the fan RF board(s). Retest. Repeat until an appropriate address is determined.
ESSENCE
RED -- SWITCHED LEG (CAPPED)
b
Wall Plate
(customer-supplied)
WWW.BIGASSFANS.COM
©2013 DELTA T CORP.
®
PE/GROUND
L2/AC NEUTRAL
L1A/AC LINE (SWITCHED LEG)
wall plate. Other brands may not be compatible.
®
a
Wall Controller
ALL RIGHTS RESERVED
Junction Box
(in wall,
customer-supplied)