Technical data
8
Performance specifications and guarantee only in connection with original spare and
replacement parts!
8.1
Phoenix 355 TDM
Setting range for welding current
Setting range for welding voltage
Duty cycle
60%
100%
Load alternation
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse
(safety fuse, slow-blow)
Mains connection lead
Max. connected load
Recommended generator rating
cos
Insulation class/protection
classification
Ambient temperature
Machine/torch cooling
Workpiece lead
Dimensions (L x W x H)
Weight
EMC class
Constructed to standards
099-005320-EW501
22.05.2014
NOTE
TIG
MIG/MAG
5 A–350 A
10,2 V - 24,0 V
14,3 V - 31,5 V
10 min. (60% DC
6 min. welding, 4 min. pause)
3 x 400 V (-25% to +20%)
H07RN-F4G2,5
10,6 kVA
-25 C to +40 C
625 mm x 300 mm x 535 mm
IEC 60974 -1, -10
Technical data
Phoenix 355 TDM
MMA
20,2 V - 34,0 V
40 °C
350 A
300 A
79 V
50/60 Hz
3 x 20 A
13,9 kVA
15,0 kVA
20,3 kVA
0.99
H/IP 23
Fan/gas
2
70 mm
41 kg
A
/
47
Need help?