Installation; Machine Cooling; Workpiece Lead, General - EWM Phoenix 355 Progress puls MM TDM Operating Instructions Manual

Welding machine
Table of Contents

Advertisement

Using protective dust caps!
Protective dust caps protect the connection sockets and therefore the machine against
dirt and damage.
The protective dust cap must be fitted if there is no accessory component being operated
on that connection.
The cap must be replaced if faulty or if lost!
Observe documentation of other system components when connecting!
5.2

Installation

Risk of accident due to improper transport of machines that may not be lifted!
Do not lift or suspend the machine! The machine can fall down and cause injuries! The
handles and brackets are suitable for transport by hand only!
The machine may not be lifted by crane or suspended!
Depending on machine type, equipment for lifting by crane or use while suspended is
available as a retrofitting option (see chapter "Accessories").
Installation site!
The machine must not be operated in the open air and must only be set up and
operated on a suitable, stable and level base!
The operator must ensure that the ground is non-slip and level, and provide sufficient
lighting for the place of work.
Safe operation of the machine must be guaranteed at all times.
5.3

Machine cooling

To obtain an optimal duty cycle from the power components, the following precautions should be
observed:
Ensure that the working area is adequately ventilated.
Do not obstruct the air inlets and outlets of the machine.
Do not allow metal parts, dust or other objects to get into the machine.
5.4

Workpiece lead, general

Risk of burns due to incorrect connection of the workpiece lead!
Paint, rust and dirt on the connection restrict the power flow and may lead to stray
welding currents.
Stray welding currents may cause fires and injuries!
Clean the connections!
Fix the workpiece lead securely!
Do not use structural parts of the workpiece as a return lead for the welding current!
Take care to ensure faultless power connections!
099-005320-EW501
22.05.2014
CAUTION
NOTE
WARNING
CAUTION
CAUTION
Design and function
Installation
21

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Phoenix 355 Progress puls MM TDM and is the answer not in the manual?

Questions and answers

Table of Contents