7.3.2
Resetting all JOBs
JOBs 1–128 and 170–256 will be reset.
Custom JOBs 129–169 are maintained.
Display
7.4
General operating problems
7.4.1
Interface for automated welding
No function of the external interrupt equipment (emergency stop switch)!
If the emergency stop circuit has been realised using an external interrupt equipment
via the interface for automated welding, the machine must be configured for this setup.
If this is not observed, the power source will ignore the external interrupt equipment
and will not shut down!
•
Disconnect jumper 1 on PCB T320/1 (Tetrix / forceTig) or M320/1 (Phoenix / alpha Q)!
099-005320-EW501
22.05.2014
ENTER
3 s
JOB-
LIST
Setting/selection
Reset to factory settings
The RESET will be done after pressing the button.
The menu will be ended when no changes are done after 3 sec.
NOTE
RESET
3 s
Figure 7-2
WARNING
Rectifying faults
General operating problems
JOB-
LIST
EXIT
3 s
45