Operating Power Limits And Ranges; Calculating Power Consumption; Calculating Heat Dissipation; Shipping Kit Contents - Sun Microsystems Sun Fire V210 Getting Started Manual

Hide thumbs Also See for Sun Fire V210:
Table of Contents

Advertisement

Operating Power Limits and Ranges

The table shows the operating power for the Sun Fire V210 and V240 servers.
Operating Power Limits and Ranges for the Sun Fire V210 and V240 Servers
TABLE 5
Description
Operating input voltage range
Operating frequency range
Maximum operating current
Maximum AC input

Calculating Power Consumption

The estimated power consumed in a fully powered server depends on the
configuration of the server. For more information on calculating power
consumption, go to the following site:
http://www.sun.com/servers/entry/v210/calc.html

Calculating Heat Dissipation

To calculate the heat generated by a server so that you can estimate the heat your
cooling system must dissipate, convert the figure for the system's power
requirement from Watts to BTU/hr. A general formula for doing this is to multiply
the power requirement figure in Watts by 3.412.

Shipping Kit Contents

The server is supplied with the components described in the following list:
Rackmount kit
Cat5 RJ-45 cable
Accessories kit
System key (V240 server only)
Antistatic wrist strap
RJ-45 to DB-9 adapter
RJ-45 to DB-25 adapter
Sun Fire V210 Server
90 - 264 Volts
47 - 63 Hz
3.58 Amps @ 90 VAC
459 Watts
Introducing the Sun Fire V210 and V240 Servers
Sun Fire V240 Server
90 - 264 Volts
47 - 63 Hz
4.17 Amps @ 90 VAC
546 Watts
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sun fire v240