Operating Power Limits and Ranges
The table shows the operating power for the Sun Fire V210 and V240 servers.
Operating Power Limits and Ranges for the Sun Fire V210 and V240 Servers
TABLE 5
Description
Operating input voltage range
Operating frequency range
Maximum operating current
Maximum AC input
Calculating Power Consumption
The estimated power consumed in a fully powered server depends on the
configuration of the server. For more information on calculating power
consumption, go to the following site:
http://www.sun.com/servers/entry/v210/calc.html
Calculating Heat Dissipation
To calculate the heat generated by a server so that you can estimate the heat your
cooling system must dissipate, convert the figure for the system's power
requirement from Watts to BTU/hr. A general formula for doing this is to multiply
the power requirement figure in Watts by 3.412.
Shipping Kit Contents
The server is supplied with the components described in the following list:
Rackmount kit
■
Cat5 RJ-45 cable
■
Accessories kit
■
System key (V240 server only)
■
Antistatic wrist strap
■
RJ-45 to DB-9 adapter
■
RJ-45 to DB-25 adapter
■
Sun Fire V210 Server
90 - 264 Volts
47 - 63 Hz
3.58 Amps @ 90 VAC
459 Watts
Introducing the Sun Fire V210 and V240 Servers
Sun Fire V240 Server
90 - 264 Volts
47 - 63 Hz
4.17 Amps @ 90 VAC
546 Watts