Booting Node Boards; Board Power-On Sequence - Sun Microsystems Netra CT 820 Administration Manual

Hide thumbs Also See for Netra CT 820:
Table of Contents

Advertisement

Booting Node Boards

Node boards can boot from a local disk or over the network.

Board Power-on Sequence

When you power on the Netra CT 820 system by pressing the power switch on the
rear of the system to the On (|) position, the boards power on in this sequence:
1. The two distributed management cards are powered on; the top card in slot 1A is
designated as the active distributed management card, and the bottom card in slot
1B is designated as the standby distributed management card. Once the cards
have booted and are ready for use, the "Ready" LED is solid green on the active
card and blinking green on the standby card.
2. The active distributed management card powers on the switching fabric boards in
slots 2 and 21. While the switching fabric boards are powering on, the blue LED
state is solid; once the boards have booted and are ready for use, the blue LED is
off.
3. The active distributed management card looks at the Boot_Mask field in the
midplane FRU ID for boot servers.
a. If one or more boot servers are designated in the Boot_Mask field, the active
distributed management card powers on the boot servers first; once the boards
have booted and are ready for use, the active distributed management card
powers on the rest of the node boards together; these boards boot from the
boot servers. The method of booting depends first on the value in the
Boot_Devices field in the midplane FRU ID or secondly on the value in the
OpenBoot PROM NVRAM boot_device configuration variable. After a board
has booted and is ready for use, "Ready" LED is solid green and the blue LED
is off.
or
b. If no boot server is designated in the Boot_Mask field, the active distributed
management card powers on all the node slots together. Once the node boards
are powered on, the method of booting depends first on the value in the
Boot_Devices field in the midplane FRU ID or secondly on the value in the
OpenBoot PROM NVRAM boot_device configuration variable. After a board
has booted and is ready for use, the "Ready" LED is solid green and the blue
LED is off.
A midplane FRU ID fault is a system fault, and no boards can be powered on.