Back-Panel Controls And Connectors; Figure 4.9 - Back Panel Controls And Connectors - AE Techron 2105 Operator's Manual

Gradient amplifier
Hide thumbs Also See for 2105:
Table of Contents

Advertisement

One or More Amps in System Main Status
Fault Status
Main Status
Reported on
Indicators
LCD Display
Run
WARNING! 
Ready
OVERVOLTAGE
Standby
Stop
4.2
Back-Panel Controls
and Connectors
This section provides an overview of Back-Panel
controls and connectors found on the 2105 ampli-
fier. Please refer to Figure 4.9 for visual locations.
AC Supply - Standard 20 amp 3-pin IEC-type
male connector.
Output Terminal Strip - Connect output lines from
the load to this 3-position terminal strip with 5 mm
screws. It accepts up to #10 AWG wire. 
BNC Input Connector - This input option provides
a standard unbalanced input. It can also be used
as a balanced input.
Input Selector Switch – When the Input Select
switch is in the LEFT position, the shield on the 
BNC connector and the inverting (–) pin on the 
terminal block connector are tied to the amplifier 
16
Indicators of
Other Amps
in System
State of Operation
Overvoltage status: This
indicates that the AC mains
voltage is more than +10% of 
nominal. All amplifiers in the 
Run
system will be forced to Standby
Ready
when an Overvoltage condition 
Standby
occurs. When the Overvoltage 
condition is cleared, the system
Stop
will automatically return to Run
mode.
Figure 4.9 – Back Panel Controls and Connectors
Information subject to change
2105 OPERATOR'S MANUAL – SECTION 4
Action Needed to Clear
Fault Condition and Re-
turn to Run Mode
To clear an Overvoltage fault 
condition, the AC mains must
be brought down to the nomi-
nal value. If the system does
not return to Run mode when
the Overvoltage condition has 
cleared, one or more amplifiers 
may require servicing. Please 
see the "Troubleshooting"
section for more information.
ground through a 4.7-ohm resistor, allowing the 
connectors to be used for Unbalanced input wir-
ing. When the Input Select switch is in the RIGHT 
position, the inverting (–) pin on the terminal block 
connector is floating, allowing the connector to be 
used for Balanced input wiring. The Input Select 
switch also functions as a Ground Lift switch for 
the BNC input connector.
Terminal Block Input Connector - This input op-
tion provides a balanced input. It can also be used
as an unbalanced input.
Interlock Connector - This 25-pin, D-sub connec-
tor is used for interlocking and combining functions 
in a multi-amp system. It can also be used for re-
mote control and monitoring applications (see the 
"Applications" section for more information). 