Back-Panel Controls & Connectors
4.2
This section provides an overview of Back-Panel 
controls and connectors found on the 8500 series
amplifier. Please refer to Figure 4.2 for component 
locations.
Unbalanced BNC Input Connector – This input 
option provides a standard unbalanced input.
Balanced WECO Input Connector – This input 
option provides a balanced input. Mating WECO 
connector is provided with the amplifier.
Current Monitor Connector – This unbalanced
BNC port allows for connection to current monitor-
ing equipment. The current monitor output is 1V = 
20A.
Voltage Monitor Connector – This unbalanced
BNC port allows for connection to voltage monitor-
ing equipment. The voltage monitor output is 1V = 
40V.
Remote Sense Port – This 2-pin terminal block 
connector provides a sense line with up to 4V of 
correction. The Remote Sense port can be useful 
when the voltage at the load must be precise. If 
the cables connecting the amplifier and the load 
are very long or under-sized, the voltage drop 
between the amplifier and  load can be corrected 
up to 4V. 
The benefits of this feature is limited to frequencies 
below 10kHz.
14
Figure 4.2 – Back Panel Controls and Connectors
Information subject to change
8508 OPERATOR'S MANUAL – SECTION 4
Output Terminals – Connect output lines from the 
load to this pair of high-current output terminals 
using 3/8-inch ring terminals. 

Back-Panel Safety Features

4.3
This section provides an overview of Back-Panel 
safety features found on the 8500 series amplifier. 
Please refer to Figure 4.3 for component loca-
tions.
AC Breakers – This switch controls the power to 
the amplifier. Place in the ON position to energize 
the amplifier system. Switch to the OFF position to 
remove power from the system. 
Magnetic Safety Switch – This door-mounted 
switch controls the power to the amplifier. When 
the amplifier's back access door is opened, power 
is removed from the amplifier system. Close the 
back access door to energize the amplifier system.
Figure 4.3 – Back Panel Safety Features