Before operating a paralleled amplifier system, the system first
must be "balanced" to ensure system stability. The balancing
process seeks to calibrate the amplifiers so they operate as
similar as possible. To prevent unwanted current and dissipation
in the amplifiers, each amplifier must have as little offset DC as
possible at no signal. In addition, the gains of the amplifiers must
be as closely matched as possible to keep the outputs from
driving each other when a signal is present.
Balancing of 7000-Series amplifiers requires access to the
amplifier main boards. Note that the main boards installed in
the 7224, 7548 and 7796 models are identical, but the
method for accessing the main board varies between models.
4.2.1 Accessing the Main Board on 7224 Amplifiers
7224 amplifiers contain an Access Panel built into the top
cover to allow easy access to the amplifier main board.
IMPORTANT: Before removing the Access Panel, make sure
the amplifier is turned off for at least 3-5 minutes and the
AC mains are disconnected.
1.
On each amplifier, locate the Access Panel as shown in
Figure 4.5. Make sure that all 8 screws are accessible.
Remove the unit from its rack, if necessary.
2.
Using a #2 Phillips screwdriver, remove the 8 screws located
on the top and side of the amplifier.
3.
Remove the Access Panel and set it aside.
4.2.2 Accessing the Main Board on 7548/7796 Amplifiers
The 7548 and 7796 amplifier's main board can be accessed by
removing the amplifier front panel.
IMPORTANT: Before removing the Front Panel, make sure the
amplifier is turned off for at least 3-5 minutes and the AC mains
are disconnected.
1
Turn the power to the amplifier "OFF".
2
Remove the four hex-head screws, located along the left and
right edges of the amplifier front panel.
3
Remove the front cover by pulling straight towards you.
4.3

Disable Gain Controls (7224 amplifiers only)

In order to ensure the amplifiers in 7224 Parallel systems
maintain a matched gain while operating, the variable gain
controls located on the amplifier front panels must be disabled.
Once disabled, each amplifier will have a fixed gain of 20. If
preferred, the gain for each amplifier can be fixed at a lower level.
18
Information subject to change
Do not attempt to access the Main Board while
the amplifier is running. Turn the amplifier off
and disconnect the AC Mains before removing
the amplifier access panel. After turning the
amplifier off, let the unit sit for 3-5 minutes to
allow the electrical charge in the power supply
capacitors to discharge.
Figure 4.5 – Access Panel Screw Locations
Do not attempt to access the Main Board while
the amplifier is running. Turn the amplifier off
and disconnect the AC Mains before removing
the amplifier front panel. After turning the
amplifier off, let the unit sit for 3-5 minutes to
allow the electrical charge in the power supply
capacitors to discharge.
Figure 4.6 – Gain Control Connection
on Main Board
97-8002465_06-09-14