Accessory Recommendations By System Type - AE Techron 2105 Operator's Manual

Gradient amplifier
Hide thumbs Also See for 2105:
Table of Contents

Advertisement

The SIM-BNC-OPTOC kit also includes a BNC
connector safety cover.
The SIM-BNC-OPTOC module is required for all 
Series configurations and should be used in con-
junction with the DB9M CABLE (see below).
DB9M CABLE – The DB9M (OPTOC) CABLE is a 
high-voltage Interlock cable that provides superior 
insulation for multi-amp series systems running 
high-voltage applications.
The DB9M CABLE is required for all Series con-
figurations and should be used in conjunction with 
the SIM-BNC-OPTOC module (see above)
BAL RES KIT – Three types available: 2105 BAL 
RES KIT, 2110 BAL RES KIT and 2120 BAL RES 
KIT. Ballast resistors are required for all Parallel 
configurations. The ballast resistor kits include one 
ballast resistor (two in the 2120 kit) with connec-
tion terminals and mounting hardware. The 2105 
6.3.1
Series Systems
2105, Two in Series:
(2) SIM-BNC-OPTOC input cards, 
(1) DB9M OPTOC cable
2105, Three in Series:
(3) SIM-BNC-OPTOC input cards, 
(2) DB9M OPTOC cables
6.3.2
Multi-Amp System Output
Capabilities (see following
pages)
Note: Performance levels typical up to 20 kHz fre-
32

Accessory Recommendations by System Type

Information subject to change
2105 OPERATOR'S MANUAL – SECTION 6
BAL RES KIT also contains the shunt required to 
defeat the amplifier's external level control. 
PARALLEL WIRING KITS – Six types available: 
2105 2-AMP, 2110/2120 2-AMP, 2105 3-AMP, 
2110/2120 3-AMP, 2105 4-AMP, and 2110/2120 
4-AMP. Parallel wiring kits include the DB-25 
Interlock cable for system communication, BNC
T-connectors and BNC patch cables for wiring 
parallel inputs through the BNC input connectors, 
and the output wiring for connecting system ampli-
fiers to the load. The kits also include the wire(s) 
needed for wiring the parallel inputs through the 
Removable Barrier Block (WECO) connectors and 
the input terminators required during system setup. 
Parallel wiring kits are recommended for all Paral-
lel configurations. 
To download the AE Techron Multi-Amp Configu-
ration Guide or for additional information, visit the
AE Techron website at www.aetechron.com.
Parallel Systems
2105 Two in Parallel:
(2) 2105 BAL RES kits, 
(1) 21050 2-AMP Parallel Wiring kit
2105 Three in Parallel:
(3) 2105 BAL RES kits, 
(1)  2105 3-AMP Parallel Wiring kit
2105 Four in Parallel:
(4) 2105 BAL RES kits, 
(1) 2105 4-AMP Parallel Wiring kit
quency levels. Above 20 kHz, slew rate may affect 
performance, reducing maximum voltage, current 
and power output.
*Indicates no testing performed.