Advanced Configuration; Configuration Access Panel; Figure 5.1 - Access Panel Screw Locations; Figure 5.2 - Main Board Location Inside Access Panel - AE Techron 2105 Operator's Manual

Gradient amplifier
Hide thumbs Also See for 2105:
Table of Contents

Advertisement

2105 OPERATOR'S MANUAL – SECTION 5

5 Advanced Configuration

The 2105 amplifier was designed to offer excep-
tional versatility in operation. You can choose from 
a range of field-configurable options, including:
Operate as a stand-alone amplifier or as part of
a multiple-amplifier system.
Operate with variable gain control or at a fixed 
gain setting of 20.
Select Controlled-Current or Controlled-Voltage 
modes of operation.
Trigger Standby mode when specified fault 
conditions occur during operation.
Select the Stop mode state at power-up, or go 
immediately to the Run mode state at power-up.
Configure for use in high voltage applications, 
high current applications, or for applications 
requiring mid-level amounts of both voltage 
and current.
Your 2105 amplifier has been pre-configured to 
your specifications before shipping from the fac-
tory. These initial settings are detailed on your 
Proof of Performance sheet and on a label located
on the side of the amplifier.
If you need to make changes to your amplifier's 
configuration, please follow the instructions con-
tained in this chapter.
5.1

Configuration Access Panel

The 2105amplifier contains an Access Panel built 
into the top cover. Most configuration settings 
can be made through this Access Panel. For your 
convenience, a #2 Phillips screwdriver is provided 
in your Toolkit for use in this procedure.
IMPORTANT: Before removing the Access
Panel, make sure the amplifier is turned off
for at least 3-5 minutes and the AC mains are
disconnected.
1. Locate the Access Panel as shown in Figure
5.1. Make sure that all 8 screws are acces-
sible. Remove the unit from its rack, if neces-
sary.
97-2105006_4-2-15
2. Using a #2 Phillips screwdriver (provided), re-
move the 8 screws located on the top and side
of the amplifier.
3. Remove the Access Panel and set it aside.
Figure 5.1 – Access Panel Screw Locations
Figure 5.2 – Main Board Location Inside 
Information subject to change
WARNING
Do not attempt to access the Main Board
while the amplifier is running. Turn the
amplifier off and disconnect the AC
Mains before removing the amplifier
front panel.
CAUTION
After turning the amplifier off, let the unit
sit for 3-5 minutes before removing the
front panel. This will allow the electrical
charge in the Power Supply capacitors
to discharge.