(5) Detaching and refitting the Top cover

Procedure
1. Remove the right upper cover, rear
upper cover R, left upper cover and rear
upper cover L
(see page 1-5-3,see page 1-5-4).
2. Remove the document processor (see
page 1-5-25) or original cover.
3. Detach the connector and two FFC
from the main PWB.
4. Release the wire from the 2 hookings
on the wire guide.
4 in 1 25/26 ppm, 3 in 1 25/26 ppm, 4 in 1 20/21 ppm
Connector (YC18)
Hook
Main PWB unit
3 in 1 20/21 ppm
Connector (YC18)
Hook
Main PWB unit
1-5-7
2M4/2M5/2M6/2M7
FFC (YC6)
FFC (YC8)
Hook
Wire guide
FFC (YC21) FFC (YC8)
Hook
Wire guide
Figure 1-5-9