Code
Contents
0030
FAX Board System Error
Cannot communicate with the
modem when activated.
*: 4 in 1 model only
0100
Backup memory read/write
error (Main NOR)
Flash returns an abnormal
status.
0120
MAC address data error
For data in which the MAC
address is invalid.
0190
Backup memory error
(engine)
Unable to read the main PWB
IC.
0630
Scan DMA error
Unable to transfer DMA.
2000
Main motor error
Pulse is not detected after
1000msec.
Motor won't stabilize after
3000msec.
3100
Scanner Carriage Error
The HP sensor won't be
opened when it is driven in the
scan direction for 37.44 mm
at the initial scanning when
the HP sensor is cut off.
The HP sensor won't be cut
off when it is driven in the
return direction for 320.44mm
at the initial scanning when
the HP sensor is open.
Causes
Defective FAX con-
Replace the fax control PWB
trol PWB.
correct operation
Defective flash
Replace the main PWB and check for cor-
memory.
rect operation (see page 1-5-18).
Defective main
Replace the main PWB and check for cor-
PWB.
rect operation (see page 1-5-18).
Defective flash
Replace the main PWB and check for cor-
memory.
rect operation (see page 1-5-18).
Defective flash
Replace the main PWB and check for cor-
memory.
rect operation (see page 1-5-18).
Defective main
Replace the main PWB and check for cor-
PWB.
rect operation (see page 1-5-18).
Defective main
Replace the main PWB and check for cor-
PWB.
rect operation (see page 1-5-18).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
main motor and Relay PWB (YC4)
Relay PWB and main PWB (YC14).
Defective drive
Check if the gears rotate smoothly. If not,
transmission sys-
grease the bushes and gears. Check for
tem of motor.
broken gears and replace if any.
Defective motor.
Replace the main motor.(see page 1-5-30)
Defective main
Replace the main PWB and check for cor-
PWB.
rect operation (see page 1-5-18).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Home position sensor and OPWB
Scanner motor and main PWB (YC18)
Defective home
Replace the home position sensor.
position sensor.
Defective scanner
Replace the scanner unit (see page 1-5-15).
motor.
Defective main
Replace the main PWB and check for cor-
PWB.
rect operation (see page 1-5-18).
1-4-6
2M4/2M5/2M6/2M7-1
Check procedures/
corrective measures
and check for
(see page 1-5-18).