Refitting The Drum Unit - Kyocera ECOSYS FS-1020MFP Service Manual

Hide thumbs Also See for ECOSYS FS-1020MFP:
Table of Contents

Advertisement

2. Remove the developer cover by raising
the levers on it.

(9) Refitting the drum unit

Procedure
1. Install the new drum unit in the machine
by holding both of its ends.
Insert the unit along the guides on both
sides.
2. Seat the drum unit in position by
pressing the knobs on its ends and
remove the drum cover.
Figure 2-4-27
Drum unit
Figure 2-4-28
Figure 2-4-29
2-4-13
2M4/2M5/2M6/2M7
Devloper cover
Lever
1
1
2
Drum cover