· Fasten the wires beneath the screw heads using the following colour scheme: Blue (N) Brown (L)
Yellow-Green
· Secure the supply cable in place with the clamp and close the cover of the terminal board.
Connecting the supply cable to the mains
Install a standardized plug corresponding to the load indicated on the data plate.
When connecting the cable directly to the mains, install an isolator. The isolator switch should be rated
according to the load and should comply with current regulations (the earth wire should not be interrupted
by the circuit breaker).
The supply cable should be positioned so that it does not reach a temperature of more than 50° C higher
than the room temperature, anywhere along its length, or should be protected by insulation sleeving with
an appropriate temperature rating.
Before switching the appliance on, please note:
· The electrical safety of this appliance can only be guaranteed if the cooker is correctly and efficiently
earthed, in compliance with local regulations on electrical safety. Always ensure that the earthing is
efficient; if you have any doubts call in a qualified electrician to check the system. The manufacturer
declines all responsibility for damage resulting from a system which has not been earthed properly.
· Check that the specifications indicated on the data plate (on the appliance and/or packaging)
corresponds to those of the electrical mains system of the home.
· Check that the electrical capacity of the system and sockets will support the maximum power of the
appliance, as indicated on the data plate. If you have any doubts, call in a qualified technician.
· If the socket and appliance plug are not compatible, have the socket replaced with a suitable model by a
qualified technician. Also ensure that the cross sections of the socket cables are suitable for the power
absorbed by the appliance. The use of adapters, multiple sockets and/or extensions, is not
recommended. All electrical work must comply with local regulation. The plug and socket must be
easily accessible.

Technical Specifications

Inner dimensions of the oven: : : :
Width 43.5cm
Depth 40cm
Height 32cm
Inner Volume of the oven 56 litres
230/240V ~50/60Hz or 50Hz
2090-2520W 2100-2550W
2100-2520W
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
Contact your local authority for information regarding the collection systems available. If electrical
appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater
and get into the food chain, damaging your health and well being.
2772-3420W
1660-2020W
2125-2560W 1220-1460W 940-1110W
2370-2924W
45-55W