MANUAL BYPASS OF THE REMOTE SYSTEM
If the remote transmitter is misplaced or lost, the appliance can be turned on manually by sliding the
three position slider switch on the wall receiver to the ON position. This will bypass the remote con-
trol feature of the system and the appliance's main burner will turn on. The fan will run at its maxi-
mum speed and the Accent Light may turn on.
To turn off the appliance, if the remote control is misplaced or lost, slide the three position slider
switch on the wall receiver to the OFF Position.
TEMPERATURE INDICATOR (
1. Press the ON/OFF Key and Turn Off the Fireplace.
2. Simultaneously, Press both the MODE Key and the Thermostat
Key.
3. Look at the LCD display to verify that your desired indicator (
o
C) is being displayed. If not, repeat step 2.
KEY LOCK FUNCTION
To prevent unsupervised children from operating the fireplace, a KEY LOCK function is
provided with this remote control system. To activate the KEY LOCK function, simultane-
ously press the "MODE KEY" and the "UP KEY". To deactivate the KEY LOCK function,
simultaneously press the "MODE KEY" and the "UP KEY".
During KEY LOCK mode, none of the Keys will function. You must DEACTIVATE the system before you can use the Re-
mote Transmitter.
LOW BATTERY POWER DETECTION
1. Transmitter Batteries: The life span of the remote control transmitter batteries depends
on various factors: quality of the batteries used, the number of ignitions of the appliance,
the number of changes to the room thermostat set point, etc. When the Transmitter bat-
teries are low, a Battery Icon will appear on the LCD display of the Transmitter before all
battery power is lost. When the batteries are replaced, this icon will disappear.
2. Wall Receiver Batteries: The life span of the wall receiver batteries depend on the quality of the batteries used and
how long the batteries have been installed in the wall receiver. These batteries are only utilized during power outages.
Replace these batteries every heating season even if you have not experienced any power outages. Batteries drain
slowly even when not in use. This is a normal characteristic of all batteries.
OPERATING DURING POWER OUTAGES
This electronic ignition system utilizes the supplied 110VAC power when it is available for all functions of this system. If
the AC power is interrupted during a power outage, this system utilizes the batteries (installed in the Wall Receiver) as
back-up batteries. During the power outage, the appliance's burners will function. In addition, Flame Height adjustment
and Secondary Burner ON/OFF functions will be available. The Fan and Accent Light, which are wholly dependent on
110VAC power, will not function.
This appliance is designed and tested to be operated during power outages. The overall efficiency of this appliance will be
reduced by approximately 5% when the blower function is disabled during the power outage period.