SPECIFICATIONS

BTUH. (MODEL DXV-45)
BTUH. (MODEL DXV-45)
NOTE: LP CONVERSION KIT #HA-42-00225 OR AA-11-01257 MUST BE PURCHASED SEPARATELY FOR THE DXV-
45 FIREPLACE TO BURN LPG.
MAIN ORIFICE:
REAR BURNER #38 NAT. GAS-#53 L.P. GAS
OVERALL EFFICIENCY
CO-AXIAL DIRECT VENT FLUE
TOTAL WEIGHT
SAFETY
GAS REQUIREMENTS SUPPLY PRESSURE: GAS INLET: 3/8" N.P.T.
NAT. GAS:
L.P. GAS:
ELECTRICAL REQUIREMENTS
ONE OF THE TWO SERVICE OUTLET BOXES INSTALLED IN THIS APPLIANCE. USE EITHER RIGHT SIDE OR LEFT
SIDE SERVICE OUTLET BOX CONNECTION.
APPROVED VENT SYSTEMS: AMERIVENT, DURAVENT, SELKIRK METALBESTOS, SECURITY CHIMNEY
Certified under ANSI Z21.88-2005•CSA 2-33-2005 and CAN/CGA 2.17 M91. DXV-45 is also deemed in compliance with
ANSI Z21.50•CSA 2.22 2000"Vented Gas Fireplace Heaters" not for use with solid fuel. Approved for bedroom installa-
tions and mobile homes. UL307B approved for "mobile homes, after first sale of home, not for recreational vehicles."
"Gas-fired appliances for use at high altitudes."
HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please con-
tact the Mendota technical service department for specific venting requirements and venting restrictions.

Building Permit and Installation Inspection Approval Requirements

INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH HOMEOWNER
4
MENDOTA, MODEL DXV-45
NAT. GAS
L.P. GAS
EXCEEDS D.O.E. EFFICIENCY REQUIREMENTS (A.F.U.E.) FOR DIRECT VENT
WALL HEATERS
5" INNER, 8" OUTER
205 POUNDS
AGA CERTIFIED IPI PILOT SAFETY SYSTEM, ACTIVATED WITH SWITCH, THERMOSTAT
OR REMOTE CONTROL.
7" W.C. (5" W.C. MIN., 11" W.C. MAX.)
12.0" W.C. (12" W.C. MIN., 14" W.C. MAX.)
120 VOLT ON LEFT OR RIGHT SIDE OF APPLIANCE. CONNECT TO ONLY
All installations of Mendota Fireplaces and Inserts must comply with all
the requirements stated in this Installation and Operating Instructions
Manual. The Dealer and/or installer must also obtain all required Building
Permits and Inspection Approval from the local building inspection de-
partment or the local body having jurisdiction. In order to validate warran-
ty coverage, Mendota may require facsimile copies of the Building Permit
and Inspection Approval forms. Failure to provide adequate proof that
the installation conforms to all local requirements and the requirements
stated in the Installation and Operating Instructions Manual will void all
applicable warranty.
High Fire - Adjustable to - Low Fire
45,000
40,000
FRONT BURNER #44 NAT. - #3/64 LP
7,500
5,000